fiw ( Fully Insulated Wire )

TECHNICAL DATA FOR FIW ACCORDING TO IEC 60317-56

IEC 60317-56 describes the full enamelled wire specification including diameters, outer diameters, mechanical, electrical, thermal and other properties such as solderability.

Test parameter Test method Specification values ​​for 0.30 mm FIW 6 Typical values ​​for 0.30 mm FIW 6
Mechanically
extension IEC 60 851-3.1 ≥ 23 % 56 %
Zugfestigkeit IEC 60 851-3.2 not specified 310 N/mm²
Springback IEC 60 851-3.4.1 not specified 68°
Solderability
at 390 °C IEC 60 851-4.5 ≤ 4 sec ≤ 3.0 sec
Heat values
Temperaturindex IEC 60 172 ≥ 180 °C 192 °C
Heat shock EC 60 851-6.3.1.1 ≥ 200 °C 220 °C/6 mm Dorn
Cut through IEC 60 851-6.4 ≥ 245 °C ≥ 260 °C
Breakdown voltage (cylinder)
Volt min. 10032 V > 15 kV
V/µm at room temperature IEC 60 851-5.4.3.2 min. 76 V/µm > 100 V/µm
at 180°C IEC 60 851-5.4.3.2 min. 53 V/µm 74 V/µm
(Volt per µm insulation increase)
TEST CONDITIONS FOR FIW ACCORDING TO UL 2353 (UL 60950)

UL 60950 is replaced by UL 62368.

UL 2353, which is very similar to the expired IEC 60950 Annex U, primarily describes electrical properties, mostly based on short-term tests.

Test conditions acc. to UL 2353
No.
Typical values ​​for 0.30 mm FIW 6
U2.1 Electrical Strength 9 6000 Vrms 1 min. (twisted pair)
U2.2 Adherence and Flexibility 10 3000 Vrms 1 min (mandrel)
U2.3 Heat Shock
225 °C x 30 min for Class B 12 3000 Vrms 1 min. (mandrel)
240 °C x 30 min for Class F
U2.4 Retention of electrical strength after bending 11
 
3000 Vrms 1 min. (mandrel)